                        | The HiMC Magnetic Contactor series employs a modular design which allows quick and simple mounting of auxiliary contact blocks, timers, mechanical latching blocks, etc. HiMC provides convenience, economic benefit and high reliability.  |  
                        |  |  
                        |  |  
                        | Superior design for industrial applications such as motor control centers, the HiMC contactor is appropriate to various control systems, and favored by shipyard and power plant; where high reliability and performance are the criteria.  |  
                        |  |  | 
        
            | 
                
                    
                        | • | Significantly extended mechanical and electrical life through increased contact capacity |  
                        | • | Noise-free operation through the use of new materials and DC control method |  
                        | • | Free voltage in control power using electronic circuits |  
                        | • | New model with high performance and reliability |  | 
        
            |  | 
        
            | HiMC 9 - HiMC 50 (Small Frame Size Contactor) | 
        
            | 
                
                    
                        |  | 
                            
                                
                                    | • | The electrical and mechanical lifetime of HiMC has been significantly extended. |  
                                    |  | New metarials prevent any generation of corroded substances, and the core maintains noise-free status with the help of special anti-rush oil treatment. |  
                                    | • | Various accessories can be attached easily. |  
                                    | • | Terminal wiring is designed to meet IEC 60529 and protection degree of IP 20. |  
                                    |  | By using clips, HiMC's coil can be replaced and its frequency is available in both 50Hz and 60Hz. |  |  | 
        
            |  | 
        
            | HiMC 65 - HiMC 800 (Large Frame Size Contactor) | 
        
            | 
                
                    
                        |  | 
                            
                                
                                    | • | The electrical and mechanical lifetime of HiMC has been significantly extended. The optimized design of the arc chamber minimizes contact erosin.
 |  
                                    |  | HiMC contactor maintains noise-free operation through the DC-control method. |  
                                    | • | HiMC contactor is available in both AC/DC and 50Hz / 60Hz with an electronic circuit which enables operation through voltage drop. |  
                                    | • | HiMC contactors canbe used in various environments by adopting special plastic (CTI/600V) which has heat & waterproof characteristics. |  
                                    | • | By adopting a cassette unit, the coil assembly can be replaced conveniently. |  
                                    |   | As the cover of HiMC contactor can be easily opened, maintenance is very conevenient. |  
                                    | • | Two auxilliary contact blocks of 1NO+1NC can be attached to each side of HiMC, allowing auxiliary contacts to be added up to 4NO+4NC. |  
                                    |  |   |  
                                    |  |  |  | 
        
            |  | 
        
            | Thermal Overload Relay (HiTH Series) | 
        
            | 
                
                    
                        |  | 
                            
                                
                                    | • | Current range covering all HiMC contactor rating 0.12 to 800 A, 9 frame sizes |  
                                    |  | Compensating ambient temperature -25C - 55C |  
                                    | • | Safety cover for main terminal & control terminal |  
                                    | • | Seperated mechanical part to increase safety |  
                                    | • | Addtional auxiliary contact 1NO+1NC (1a1b) |  
                                    |   | Three operational to indicate relay status |  
                                    | • | Built-in trip free mechanism to make trip at any position |  
                                    | • | Differential trip feature for effective motor protection, 40-60% of trip time at phase loss |  
                                    | • | Seperate mounting unit to mount separately with screws or DIN rail |  |  | 
        
            |  | 
        
            | Digital Motor Protection Relay (HiMP Series) | 
        
            |  | 
        
            | 
                
                    
                        | Economic Type | Standard Type | Deluxe Type |  
                        | 1) Various Protective Function- Over current
 - Under current
 - Phase failure
 - Phase unbalance
 - Restriction
 
 2) Various Wiring Method
 - Tunnel type
 - Terminal screw type
 - Dorect connection type
 
 | 1) Various Protective Function - Over current
 - Under current
 - Phase failure
 - Phase unbalance
 - Reverse phase
 - Stall & Lock
 
 2) Various Wiring Method
 - Tunnel type
 - Terminal screw type
 - Dorect connection type
 
 | 1) Various Protective Function- Over current & Under current
 - Phase failure & Phaseunbalance
 - Reverse phase & Stalll & Lock
 - Earth leakage r short circuit (Option)
 
 2) Alert Function
 - Overload alert
 - Accumulated operating time alert
 - Setting time alert
 
 3) Display Function
 - Display ampere
 - Trip cause & Trip current
 - Seperable display part
 
 4) Various Wiring Method
 - Terminal screw type
 - Tunnel type
 
 5) Trip Characteristic
 - Selectable inverse & definite
 
 
 
 |  |